  "db_version": "1.0.0",
  "release_date": "2026-11-17",
  "architecture": {
    "local_zero_upload": true,
    "hk_sync_endpoint": "https://8.218.89.247:8788/esia-db/v1/layer0_ifc_ep4_gb.json"
  },
  "records": {
    "IFC_PS_EP4_GOVERNANCE": {
      "ifc_ps_2012": {
        "standards": [
          "PS1 Assessment & ESMS",
          "PS2 Labor",
          "PS3 Resource Efficiency & Pollution Prevention",
          "PS4 Community Health/Safety/Security",
          "PS5 Land Acquisition",
          "PS6 Biodiversity (Net Gain in Critical Habitat)",
          "PS7 Indigenous Peoples (FPIC)",
          "PS8 Cultural Heritage"
        ],
        "source_url": "https://www.ifc.org/content/dam/ifc/doc/2023/ifc-performance-standards-2012-en.pdf"
      },
      "equator_principles_ep4": {
        "project_finance_threshold_usd": 10000000,
        "iesc_mandatory": [
          "Category A",
          "High-risk Category B"
        ],
        "ccra_mandatory": true,
        "ghg_public_reporting_mandatory_tco2e_yr": 100000,
        "ghg_public_reporting_encouraged_tco2e_yr": 25000,
        "source_urls": [
          "https://equator-principles.com/app/uploads/The-Equator-Principles_EP4_July2020.pdf",
          "https://equator-principles.com/app/uploads/Guidance-CCRA_May-2023.pdf",
          "https://equator-principles.com/app/uploads/Good-Practice-Note_Role-of-ES-Agent_Jul2025.pdf"
        ]
      },
      "china_overseas_guideline": {
        "doc_number": "环办环评〔2022〕2号",
        "title": "对外投资合作建设项目生态环境保护指南",
        "rule": "Comply with host-country laws; adopt international multilateral or Chinese standards where host-country technical standards are absent.",
        "source_url": "https://www.mee.gov.cn/xxgk2018/xxgk/xxgk05/202201/t20220110_966571.html"
      }
    },
    "IFC_GENERAL_EHS_2007": {
      "ambient_air_increment_cap_pct": 25.0,
      "gep_stack_formula": "HG = H + 1.5 * L (structures within 5L and <800 m)",
      "noise_limits": [
        {
          "receptor": "Residential/Institutional/Educational",
          "day_07_22_dBA": 55,
          "night_22_07_dBA": 45,
          "max_bg_increase_dB": 3,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-noise-en.pdf"
        },
        {
          "receptor": "Industrial/Commercial",
          "day_07_22_dBA": 70,
          "night_22_07_dBA": 70,
          "max_bg_increase_dB": 3,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-noise-en.pdf"
        }
      ],
      "who_ambient_air_ug_m3": [
        {
          "parameter": "SO2",
          "24h_it1": 125,
          "24h_it2": 50,
          "24h_guideline": 20,
          "10m_guideline": 500,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf"
        },
        {
          "parameter": "NO2",
          "1yr_guideline": 40,
          "1h_guideline": 200,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf"
        },
        {
          "parameter": "PM10",
          "1yr_it1": 70,
          "1yr_guideline": 20,
          "24h_it1": 150,
          "24h_guideline": 50,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf"
        },
        {
          "parameter": "PM2.5",
          "1yr_it1": 35,
          "1yr_guideline": 10,
          "24h_it1": 75,
          "24h_guideline": 25,
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf"
        }
      ],
      "sanitary_wastewater_limits": [
        {
          "parameter": "pH",
          "medium": "effluent",
          "value": null,
          "min_value": 6.0,
          "max_value": 9.0,
          "unit": "S.U.",
          "speciation": "pH",
          "averaging_period": "grab",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "BOD5",
          "medium": "effluent",
          "value": 30.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "COD",
          "medium": "effluent",
          "value": 125.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Total_Nitrogen",
          "medium": "effluent",
          "value": 10.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Total_Phosphorus",
          "medium": "effluent",
          "value": 2.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Oil_and_Grease",
          "medium": "effluent",
          "value": 10.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "grab",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "TSS",
          "medium": "effluent",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Total_Coliform",
          "medium": "effluent",
          "value": 400.0,
          "min_value": null,
          "max_value": null,
          "unit": "MPN/100mL",
          "speciation": "MPN",
          "averaging_period": "grab",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS 2007 Table 1.3.1",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-wastewater-and-ambient-water-quality-en.pdf",
          "notes": ""
        }
      ],
      "small_combustion_3_50MWth": [
        {
          "parameter": "NOx_Gas_Boiler",
          "medium": "air_stack",
          "value": 320.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "annual_or_continuous",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 3.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS Table 1.1.2",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "PM_Solid_Boiler",
          "medium": "air_stack",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "annual_or_continuous",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS Table 1.1.2",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf",
          "notes": "Up to 150 mg/Nm3 if justified by EA"
        },
        {
          "parameter": "SO2_Solid_Boiler",
          "medium": "air_stack",
          "value": 2000.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "annual_or_continuous",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS Table 1.1.2",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "NOx_Solid_Boiler",
          "medium": "air_stack",
          "value": 650.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "annual_or_continuous",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS Table 1.1.2",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf",
          "notes": ""
        },
        {
          "parameter": "PM_Liquid_Engine",
          "medium": "air_stack",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "annual_or_continuous",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 15.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "IFC General EHS Table 1.1.2",
          "effective_date": "2007-04-30",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-general-ehs-guidelines-air-emissions-and-ambient-air-quality-en.pdf",
          "notes": "Bore <400mm NOx=1460; >=400mm NOx=1850 mg/Nm3"
        }
      ]
    },
    "WBG_MINING_2007": {
      "sector": "mining",
      "giip_clauses": {
        "temp_drainage_design_storm": "25-year / 24-hour event minimum",
        "perm_drainage_design_storm": "100-year / 24-hour event",
        "tailings_flood_design": "ICOLD/ANCOLD + Probable Maximum Flood (PMF) freeboard",
        "riverine_shallow_marine_tailings": "Not considered GIIP; DSTP only if land-based alternatives proven infeasible with no significant benthic impact",
        "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf"
      },
      "numeric_limits": [
        {
          "parameter": "pH",
          "medium": "effluent",
          "value": null,
          "min_value": 6.0,
          "max_value": 9.0,
          "unit": "S.U.",
          "speciation": "pH",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "TSS",
          "medium": "effluent",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "COD",
          "medium": "effluent",
          "value": 150.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "BOD5",
          "medium": "effluent",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Oil_and_Grease",
          "medium": "effluent",
          "value": 10.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Arsenic",
          "medium": "effluent",
          "value": 0.1,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Cadmium",
          "medium": "effluent",
          "value": 0.05,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Chromium_VI",
          "medium": "effluent",
          "value": 0.1,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "hexavalent",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Copper",
          "medium": "effluent",
          "value": 0.3,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Cyanide_Total",
          "medium": "effluent",
          "value": 1.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Cyanide_Free",
          "medium": "effluent",
          "value": 0.1,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "free",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Cyanide_WAD",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "WAD",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Iron",
          "medium": "effluent",
          "value": 2.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Lead",
          "medium": "effluent",
          "value": 0.2,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Mercury",
          "medium": "effluent",
          "value": 0.002,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Nickel",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Phenols",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Zinc",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "95pct_operating_hours_no_dilution",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Temp_Differential",
          "medium": "effluent",
          "value": 3.0,
          "min_value": null,
          "max_value": null,
          "unit": "degC",
          "speciation": "delta_T",
          "averaging_period": "edge_of_mixing_zone",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Mining EHS 2007 Table 1",
          "effective_date": "2007-12-10",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2007-mining-ehs-guidelines-en.pdf",
          "notes": ""
        }
      ]
    },
    "WBG_THERMAL_POWER_2008": {
      "sector": "power",
      "giip_clauses": {
        "cooling_intake_screen_velocity_max_m_s": 0.15,
        "once_through_plume_model_trigger_MWth": 1200,
        "occupational_emf_50Hz": {
          "electric_V_m": 10000,
          "magnetic_uT": 500
        },
        "occupational_emf_60Hz": {
          "electric_V_m": 8300,
          "magnetic_uT": 415
        },
        "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf"
      },
      "numeric_limits": [
        {
          "parameter": "PM_Coal_Boiler_50_600MWth",
          "medium": "air_stack",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "PM_Coal_Boiler_50_600MWth",
          "medium": "air_stack",
          "value": 30.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "DA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "SO2_Coal_Boiler_50_600MWth",
          "medium": "air_stack",
          "value": 900.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": "Range 900-1500 mg/Nm3 in NDA"
        },
        {
          "parameter": "SO2_Coal_Boiler_50_600MWth",
          "medium": "air_stack",
          "value": 400.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "DA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "SO2_Coal_Boiler_ge600MWth",
          "medium": "air_stack",
          "value": 200.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "DA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": "NDA range 200-850 mg/Nm3"
        },
        {
          "parameter": "NOx_Coal_Boiler",
          "medium": "air_stack",
          "value": 510.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "NDA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": "Up to 1100 mg/Nm3 if volatile matter <10%"
        },
        {
          "parameter": "NOx_Coal_Boiler",
          "medium": "air_stack",
          "value": 200.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 6.0,
          "excess_air_alpha": null,
          "airshed_class": "DA",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "NOx_NatGas_Turbine_gt50MWth",
          "medium": "air_stack",
          "value": 51.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 15.0,
          "excess_air_alpha": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(B)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": "25 ppmv at 15% O2"
        },
        {
          "parameter": "NOx_NatGas_Boiler_gt50MWth",
          "medium": "air_stack",
          "value": 240.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/Nm3",
          "speciation": "gas_or_pm",
          "averaging_period": "1h_95pct",
          "ref_temp_K": 273.15,
          "ref_pressure_kPa": 101.325,
          "dry_gas": true,
          "ref_O2_pct": 3.0,
          "excess_air_alpha": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 6(C)",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "TSS",
          "medium": "effluent",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Oil_and_Grease",
          "medium": "effluent",
          "value": 10.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Total_Residual_Chlorine",
          "medium": "effluent",
          "value": 0.2,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": "Shock dosing max 2.0 mg/L up to 2 hrs"
        },
        {
          "parameter": "Copper",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Iron",
          "medium": "effluent",
          "value": 1.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Zinc",
          "medium": "effluent",
          "value": 1.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Chromium_Total",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Cadmium",
          "medium": "effluent",
          "value": 0.1,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Mercury",
          "medium": "effluent",
          "value": 0.005,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Arsenic",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "Lead",
          "medium": "effluent",
          "value": 0.5,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "monthly_avg",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "ALL",
          "source_standard": "WBG Thermal Power 2008 Table 5",
          "effective_date": "2008-12-19",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2000/2008-thermal-power-ehs-guidelines-en.pdf",
          "notes": ""
        }
      ]
    },
    "WBG_PORTS_2017": {
      "sector": "ports",
      "giip_clauses": {
        "dredging_plume_management": "Dredging Management Plan with near-field & far-field suspended sediment dispersion modeling (concentration-time exposure thresholds at coral reefs, seagrass, benthic habitats) per IMO London Convention/Protocol (1972/1996) & PIANC Report 100/108",
        "vessel_waste_ballast": "MARPOL 73/78 port reception facilities (oily bilge, sewage, garbage) and IMO Ballast Water Management (BWM) Convention compliance",
        "underwater_piling_noise": "Soft-start/ramp-up procedures, Marine Mammal Observers (MMO) safety exclusion zone, and bubble curtains / cofferdams for offshore pile driving",
        "coastal_hydromorphology": "Littoral drift / shoreline erosion numerical modeling + climate change sea-level rise & storm surge resilience",
        "port_stormwater_oil_separator": "Oil-water separators & silt traps on terminal/yard runoff prior to discharge (Oil & Grease <= 10 mg/L, TSS <= 50 mg/L per General EHS)",
        "source_url": "https://www.ifc.org/content/dam/ifc/doc/2010/2017-ports-harbors-terminals-ehs-guidelines-en.pdf"
      },
      "numeric_limits": [
        {
          "parameter": "Oil_and_Grease",
          "medium": "effluent",
          "value": 10.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "grab",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "MARINE",
          "source_standard": "WBG Ports EHS 2017 / General EHS",
          "effective_date": "2017-02-02",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2010/2017-ports-harbors-terminals-ehs-guidelines-en.pdf",
          "notes": ""
        },
        {
          "parameter": "TSS",
          "medium": "effluent",
          "value": 50.0,
          "min_value": null,
          "max_value": null,
          "unit": "mg/L",
          "speciation": "total",
          "averaging_period": "24h_composite",
          "ref_temp_K": null,
          "ref_pressure_kPa": null,
          "dry_gas": null,
          "ref_O2_pct": null,
          "airshed_class": "ALL",
          "receiving_water_type": "MARINE",
          "source_standard": "WBG Ports EHS 2017 / General EHS",
          "effective_date": "2017-02-02",
          "source_url": "https://www.ifc.org/content/dam/ifc/doc/2010/2017-ports-harbors-terminals-ehs-guidelines-en.pdf",
          "notes": ""
        }
      ]
    },
    "CHINA_GB_BASELINE": {
      "GB_25467_2010_Cu_Ni_Co": {
        "standard_condition": "273.15 K, 101.325 kPa, dry gas, furnace excess air alpha=1.7",
        "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
        "numeric_limits": [
          {
            "parameter": "pH",
            "medium": "effluent",
            "value": null,
            "min_value": 6.0,
            "max_value": 9.0,
            "unit": "S.U.",
            "speciation": "pH",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (New Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": ""
          },
          {
            "parameter": "TSS",
            "medium": "effluent",
            "value": 80.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (Mining/Beneficiation Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Smelting/Other=30 mg/L; Table 3 Special=30 mg/L (Mining)"
          },
          {
            "parameter": "COD",
            "medium": "effluent",
            "value": 100.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (Hydrometallurgy Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Other=60 mg/L; Table 3 Special=50 mg/L"
          },
          {
            "parameter": "Oil_and_Grease",
            "medium": "effluent",
            "value": 3.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "petroleum",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Petroleum hydrocarbons; Table 3 Special=1.0 mg/L"
          },
          {
            "parameter": "Copper",
            "medium": "effluent",
            "value": 0.5,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=0.2 mg/L"
          },
          {
            "parameter": "Zinc",
            "medium": "effluent",
            "value": 1.5,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "daily_or_grab",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2 (Direct)",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=1.0 mg/L"
          },
          {
            "parameter": "Lead",
            "medium": "effluent",
            "value": 0.5,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=0.2 mg/L"
          },
          {
            "parameter": "Cadmium",
            "medium": "effluent",
            "value": 0.1,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=0.02 mg/L"
          },
          {
            "parameter": "Nickel",
            "medium": "effluent",
            "value": 0.5,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": ""
          },
          {
            "parameter": "Arsenic",
            "medium": "effluent",
            "value": 0.5,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=0.1 mg/L"
          },
          {
            "parameter": "Mercury",
            "medium": "effluent",
            "value": 0.05,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": "Table 3 Special=0.01 mg/L"
          },
          {
            "parameter": "Cobalt",
            "medium": "effluent",
            "value": 1.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/L",
            "speciation": "total",
            "averaging_period": "workshop_outlet",
            "ref_temp_K": null,
            "ref_pressure_kPa": null,
            "dry_gas": null,
            "ref_O2_pct": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 2",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": ""
          },
          {
            "parameter": "PM_Crushing_Screening",
            "medium": "air_stack",
            "value": 100.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "stack",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": null,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 5",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": ""
          },
          {
            "parameter": "SO2_Smelting",
            "medium": "air_stack",
            "value": 400.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "stack",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": null,
            "excess_air_alpha": 1.7,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 25467-2010 Table 5",
            "effective_date": "2010-10-01",
            "source_url": "https://sthjj.bynr.gov.cn/zwgk/zdxxgk/wryjg/201404/P020260709756981296129.pdf",
            "notes": ""
          }
        ]
      },
      "GB_13223_2011_Thermal_Power": {
        "standard_condition": "273.15 K, 101.325 kPa, dry gas; 6% O2 (coal boiler), 3% O2 (oil/gas boiler), 15% O2 (gas turbine)",
        "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
        "numeric_limits": [
          {
            "parameter": "PM_Coal_Boiler",
            "medium": "air_stack",
            "value": 30.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 6.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": "Table 2 Key Region=20 mg/m3"
          },
          {
            "parameter": "SO2_Coal_Boiler",
            "medium": "air_stack",
            "value": 100.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 6.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": "200 in GX/CQ/SC/GZ; Table 2 Key Region=50 mg/m3"
          },
          {
            "parameter": "NOx_Coal_Boiler",
            "medium": "air_stack",
            "value": 100.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 6.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": ""
          },
          {
            "parameter": "Hg_Coal_Boiler",
            "medium": "air_stack",
            "value": 0.03,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 6.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": ""
          },
          {
            "parameter": "NOx_NatGas_Turbine",
            "medium": "air_stack",
            "value": 50.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 15.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": ""
          },
          {
            "parameter": "NOx_NatGas_Boiler",
            "medium": "air_stack",
            "value": 100.0,
            "min_value": null,
            "max_value": null,
            "unit": "mg/m3",
            "speciation": "gas_or_pm",
            "averaging_period": "continuous",
            "ref_temp_K": 273.15,
            "ref_pressure_kPa": 101.325,
            "dry_gas": true,
            "ref_O2_pct": 3.0,
            "excess_air_alpha": null,
            "airshed_class": "ALL",
            "receiving_water_type": "ALL",
            "source_standard": "GB 13223-2011 Table 1 (New)",
            "effective_date": "2012-01-01",
            "source_url": "https://english.mee.gov.cn/Resources/standards/Air_Environment/Emission_standard1/201201/W020110923324406748154.pdf",
            "notes": ""
          }
        ]
      }
    }
  }
}